Originální název
Hygrothermal Loads of Building Components in Bathroom of Dwellings
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
The paper presents an analysis of indoor temperature and relative humidity measurements in dwelling's bathroom. Obtained data are compared with those defined in technical standards and applied for assessment of building component from building physics point of view. These parameters are used for boundary condition at the evaluation level of building components and their values have significant influence on hygrothermal assessment. The example of building's component demonstrates analysis magnitude of differences between the calculation results applying standardized boundaries condition and monitored data based on in-situ measurements. Temperature and humidity measurements are applied for prediction of hygrothermal behaviour of building’s component by HAM algorithm. Finally, results from analysis presents the penetration depth of moisture increasing at surface caused by moisture peaks in internal environment of bathroom.
Klíčová slova
Bathroom, Hygrothermal Assessment, Moisture
Autoři
SLÁVIK, R.; ČEKON, M.
Rok RIV
2014
Vydáno
1. 10. 2014
Nakladatel
Trans Tech Publications
Místo
Switzerland
ISBN
978-3-03835-280-8
Kniha
enviBUILD 2014
ISSN
1022-6680
Periodikum
Advanced Materials Research
Ročník
1041
Stát
Švýcarská konfederace
Strany od
273
Strany do
276
Strany počet
4
BibTex
@inproceedings{BUT109806, author="Richard {Slávik} and Miroslav {Čekon}", title="Hygrothermal Loads of Building Components in Bathroom of Dwellings", booktitle="enviBUILD 2014", year="2014", journal="Advanced Materials Research", volume="1041", pages="273--276", publisher="Trans Tech Publications", address="Switzerland", doi="10.4028/www.scientific.net/AMR.1041.273", isbn="978-3-03835-280-8", issn="1022-6680" }