Detail publikace

Evaluation of Load Impedances, Discontinuity and Impedance Mismatch in PLC Networks by Experimental Measurements with Coupling Circuits

MLÝNEK, P. KOUTNÝ, M. MIŠUREC, J. FUJDIAK, R.

Originální název

Evaluation of Load Impedances, Discontinuity and Impedance Mismatch in PLC Networks by Experimental Measurements with Coupling Circuits

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

Two different coupling circuits, capacitive and inductive, are introduced. These coupling circuits are analyzed by laboratory measurements. The measurements of the load impedance of coupling circuits are realized. The general discontinuity in communication path is presented in form of coupling circuit. The influence of position of coupling circuit and number of branches on transfer function is also demonstrated. In addition, the simple model of coupling circuit was designed and the effect of discontinuity and impedance mismatch will be shown on the multipath model.

Klíčová slova

Power line communication, coupling circuit, transfer function, measurement, load impedance, discontinuity

Autoři

MLÝNEK, P.; KOUTNÝ, M.; MIŠUREC, J.; FUJDIAK, R.

Rok RIV

2014

Vydáno

9. 7. 2015

Místo

Berlin, Germany

ISBN

978-1-4799-8497-8

Kniha

Proceedings of the 38th International Conference on Telecommunication and Signal Processing

Strany od

657

Strany do

661

Strany počet

5

URL

BibTex

@inproceedings{BUT110174,
  author="Petr {Mlýnek} and Martin {Koutný} and Jiří {Mišurec} and Radek {Fujdiak}",
  title="Evaluation of Load Impedances, Discontinuity and Impedance Mismatch in PLC Networks by Experimental Measurements with Coupling Circuits",
  booktitle="Proceedings of the 38th International Conference on Telecommunication and Signal Processing",
  year="2015",
  pages="657--661",
  address="Berlin, Germany",
  doi="10.1109/TSP.2015.7296345",
  isbn="978-1-4799-8497-8",
  url="https://ieeexplore.ieee.org/document/7296345"
}