Detail publikačního výsledku

Electrochemical characterisation of nanoparticulate zirconium dioxide-on-gold electrode for electrochemical detection in flow-based analytical systems

ISLAM, M.; ATIA, M.; MACKA, M.; PAULL, B.; MAHBUB, P.

Originální název

Electrochemical characterisation of nanoparticulate zirconium dioxide-on-gold electrode for electrochemical detection in flow-based analytical systems

Anglický název

Electrochemical characterisation of nanoparticulate zirconium dioxide-on-gold electrode for electrochemical detection in flow-based analytical systems

Druh

Článek WoS

Originální abstrakt

The modification of gold (Au) electrode using zirconium dioxide nanoparticles (ZrO2 NPs) has been investigated for enhanced electrochemical (EC) detection in flow-based analytical systems. The average size of ZrO2 NPs deposited in a facile procedure on the Au electrode surface was calculated as 22.5 +/- 7 nm. Redox behaviour of a test solute, ferrocyanide [Fe(CN)(6)](4-), on the bare- and ZrO2-Au electrodes was initially investigated using cyclic voltammetry. From the voltammograms of bare- and ZrO2-Au electrodes, the EC reversibility values and effective surface area were experimentally determined for the first-time in this study. Further, EC reversibility and 100% increase in effective electrode surface area were confirmed in ZrO2-Au electrode through investigating the detection response (current). The EC performance of the ZrO2-Au electrode was then investigated in amperometric detection of selected electroactive solutes separated by reversed-phase HPLC. The limits of detection (LODs), based upon an injection volume of 10 mu L for ascorbic acid, 2,3-dihydroxybenzoic acid and pyrocatechol were 0.09 mu M, 0.04 mu M, and 0.10 mu M, respectively (RSD 2.5%, n = 9, r(2) = 0.99 for concentration range 1-100 mu M). These LODs for the ZrO2-Au electrode were 2-times lower for 2,3-DHBA, and pyrocatechol than the lowest LODs reported in the literature for EC detection in HPLC. The ZrO2-Au electrode demonstrated satisfactory repeatability of preparation, detection reproducibility and high stability (8.5 h) during continuous-flow in FIA and 45 days during intermittent use with HPLC, at flow rate of 0.6 mL min(-1). This work has demonstrated a comprehensive EC characterisation of Au electrode with nanoparticulate ZrO2 for flow-based analytical systems.

Anglický abstrakt

The modification of gold (Au) electrode using zirconium dioxide nanoparticles (ZrO2 NPs) has been investigated for enhanced electrochemical (EC) detection in flow-based analytical systems. The average size of ZrO2 NPs deposited in a facile procedure on the Au electrode surface was calculated as 22.5 +/- 7 nm. Redox behaviour of a test solute, ferrocyanide [Fe(CN)(6)](4-), on the bare- and ZrO2-Au electrodes was initially investigated using cyclic voltammetry. From the voltammograms of bare- and ZrO2-Au electrodes, the EC reversibility values and effective surface area were experimentally determined for the first-time in this study. Further, EC reversibility and 100% increase in effective electrode surface area were confirmed in ZrO2-Au electrode through investigating the detection response (current). The EC performance of the ZrO2-Au electrode was then investigated in amperometric detection of selected electroactive solutes separated by reversed-phase HPLC. The limits of detection (LODs), based upon an injection volume of 10 mu L for ascorbic acid, 2,3-dihydroxybenzoic acid and pyrocatechol were 0.09 mu M, 0.04 mu M, and 0.10 mu M, respectively (RSD 2.5%, n = 9, r(2) = 0.99 for concentration range 1-100 mu M). These LODs for the ZrO2-Au electrode were 2-times lower for 2,3-DHBA, and pyrocatechol than the lowest LODs reported in the literature for EC detection in HPLC. The ZrO2-Au electrode demonstrated satisfactory repeatability of preparation, detection reproducibility and high stability (8.5 h) during continuous-flow in FIA and 45 days during intermittent use with HPLC, at flow rate of 0.6 mL min(-1). This work has demonstrated a comprehensive EC characterisation of Au electrode with nanoparticulate ZrO2 for flow-based analytical systems.

Klíčová slova

Electrochemical detection; Flow-based analytical systems; Nanomaterials; Zirconium dioxide

Klíčová slova v angličtině

Electrochemical detection; Flow-based analytical systems; Nanomaterials; Zirconium dioxide

Autoři

ISLAM, M.; ATIA, M.; MACKA, M.; PAULL, B.; MAHBUB, P.

Rok RIV

2020

Vydáno

20.09.2019

ISSN

0013-4686

Periodikum

ELECTROCHIMICA ACTA

Svazek

318

Číslo

1

Stát

Spojené království Velké Británie a Severního Irska

Strany od

61

Strany do

68

Strany počet

8

URL

BibTex

@article{BUT158408,
  author="Muhammed Ariful {Islam} and Mostafa A. {Atia} and Miroslav {Macka} and Brett {Paull} and Parvez {Mahbub}",
  title="Electrochemical characterisation of nanoparticulate zirconium dioxide-on-gold electrode for electrochemical detection in flow-based analytical systems",
  journal="ELECTROCHIMICA ACTA",
  year="2019",
  volume="318",
  number="1",
  pages="61--68",
  doi="10.1016/j.electacta.2019.06.031",
  issn="0013-4686",
  url="https://www.sciencedirect.com/science/article/pii/S0013468619311740?via%3Dihub"
}

Dokumenty