Detail publikace

Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System

JIŘÍČEK, S. KOUDELKA, V. LÁČÍK, J. VEJMOLA, Č. KUŘÁTKO, D. WÓJCIK, D. RAIDA, Z. HLINKA, J. PÁLENÍČEK, T.

Originální název

Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System

Typ

článek v časopise ve Web of Science, Jimp

Jazyk

angličtina

Originální abstrakt

This work presents and evaluates a 12-electrode intracranial electroencephalography system developed at the National Institute of Mental Health (Klecany, Czech Republic) in terms of an electrical source imaging (ESI) technique in rats. The electrode system was originally designed for translational research purposes. This study demonstrates that it is also possible to use this well-established system for ESI, and estimates its precision, accuracy, and limitations. Furthermore, this paper sets a methodological basis for future implants. Source localization quality is evaluated using three approaches based on surrogate data, physical phantom measurements, and in vivo experiments. The forward model for source localization is obtained from the FieldTrip-SimBio pipeline using the finite-element method. Rat brain tissue extracted from a magnetic resonance imaging template is approximated by a single-compartment homogeneous tetrahedral head model. Four inverse solvers were tested: standardized low-resolution brain electromagnetic tomography, exact low-resolution brain electromagnetic tomography (eLORETA), linear constrained minimum variance (LCMV), and dynamic imaging of coherent sources. Based on surrogate data, this paper evaluates the accuracy and precision of all solvers within the brain volume using error distance and reliability maps. The mean error distance over the whole brain was found to be the lowest in the eLORETA solution through signal to noise ratios (SNRs) (0.2 mm for 25 dB SNR). The LCMV outperformed eLORETA under higher SNR conditions, and exhibiting higher spatial precision. Both of these inverse solvers provided accurate results in a phantom experiment (1.6 mm mean error distance across shallow and 2.6 mm across subcortical testing dipoles). Utilizing the developed technique in freely moving rats, an auditory steady-state response experiment provided results in line with previously reported findings. The obtained results support the idea of utilizing a 12-electrode system for ESI and using it as a solid basis for the development of future ESI dedicated implants.

Klíčová slova

Electroencephalography; preclinical models; electrical source imaging; translational research; auditory steady-state response experiment; fieldtrip

Autoři

JIŘÍČEK, S.; KOUDELKA, V.; LÁČÍK, J.; VEJMOLA, Č.; KUŘÁTKO, D.; WÓJCIK, D.; RAIDA, Z.; HLINKA, J.; PÁLENÍČEK, T.

Vydáno

25. 1. 2021

Nakladatel

Frontiers

Místo

Lausanne, Switzerland

ISSN

1662-5196

Periodikum

Frontiers in Neuroinformatics

Ročník

14

Číslo

1

Stát

Švýcarská konfederace

Strany od

1

Strany do

22

Strany počet

22

URL

Plný text v Digitální knihovně

BibTex

@article{BUT168939,
  author="Stanislav {Jiříček} and Vlastimil {Koudelka} and Jaroslav {Láčík} and Čestmír {Vejmola} and David {Kuřátko} and Daniel Krzysztof {Wójcik} and Zbyněk {Raida} and Jaroslav {Hlinka} and Tomáš {Páleníček}",
  title="Electrical Source Imaging in Freely Moving Rats: Evaluation of a 12-Electrode Cortical Electroencephalography System",
  journal="Frontiers in Neuroinformatics",
  year="2021",
  volume="14",
  number="1",
  pages="1--22",
  doi="10.3389/fninf.2020.589228",
  issn="1662-5196",
  url="https://www.frontiersin.org/articles/10.3389/fninf.2020.589228/full"
}