Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
Yang, L., Zhang, B., Klemeš, J.J., Liu, J., Song, M., Wang, J.
Originální název
Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Many researchers numerically investigated U-tube underground heat exchanger using a two-dimensional simplified pipe. However, a simplified model results in large errors compared to the data from construction sites. This research is carried out using a three-dimensional full-size model. A model validation is conducted by comparing with experimental data in summer. This article investigates the effects of fluid velocity and buried depth on the heat exchange rate in a vertical U-tube underground heat exchanger based on fluid-structure coupled simulations. Compared with the results at a flow rate of 0.4 m/s, the results of this research show that the heat transfer per buried depth at 1.0 m/s increases by 123.34%. With the increase of the buried depth from 80 to 140 m, the heat transfer per unit depth decreases by 9.72%. © 2021 Li Yang et al., published by De Gruyter 2021.
Klíčová slova
buried depth; computational fluid dynamics; fluid velocity; ground source heat pump; U-tube heat exchanger
Autoři
Vydáno
1. 1. 2021
Nakladatel
De Gruyter
ISSN
2391-5471
Periodikum
Open Physics
Ročník
1
Číslo
19
Stát
Polská republika
Strany od
327
Strany do
330
Strany počet
4
URL
https://www.degruyter.com/document/doi/10.1515/phys-2021-0033/html
BibTex
@article{BUT172044, author="Jiří {Klemeš} and Jin {Wang}", title="Effect of buried depth on thermal performance of a vertical U-tube underground heat exchanger", journal="Open Physics", year="2021", volume="1", number="19", pages="327--330", doi="10.1515/phys-2021-0033", issn="2391-5471", url="https://www.degruyter.com/document/doi/10.1515/phys-2021-0033/html" }