Originální abstrakt
Photovoltaic solar-based facade concepts are considered one of the promising representatives in the overall energy-saving campaign. The presented study aims at the simulation approach and its validation relative to experimental measurements of a double-skin building-integrated photovoltaic (BiPV) concept coupled with phase change material (PCM) in climate-responsive facade design. A comparative study of the thermo-responsive reactions and electricity production of two BiPV facades (with and without PCM layer) was conducted using the building energy simulation (BES) method to reveal the complexity of building performance predictions. An empirical validation of the BES tool working under the EnergyPlus computational engine is conducted in this connection. The consistency between the simulation results and the experimental data obtained via calorimetry and dynamic outdoor tests is comprehensively investigated. The current zonal modelling approach of the BES method is suitable when predicting the thermo-responsive capabilities of a PCM-based BiPV facade. Accordingly, the best agreement is found in the PCM data based on Triple-layer calorimetry (3LC). Using PCM in a BiPV system can increase the maximum peak electricity production from 4.3 to 4.8 % obtained experimentally with a 10-14 K decrease in PV panel operating temperature. In contrast, a difference, from 3.8 to 5.4 %, is observed with the equivalent one-diode model between the simulation results for solar panels based on copper-in-dium-gallium-selenide (CIGS) technology. Hence, the performance prediction of PV electrical conversion effi-ciency is calibrated using a semiconductor band gap at a value of 1.4 eV.
Klíčová slova
Building-integrated photovoltaics; Thermal energy storage; PCM; Latent heat capacity; Building energy simulation; EnergyPlus
Autoři
ČURPEK, J.; ČEKON, M.
Vydáno
10. 12. 2022
Nakladatel
ELSEVIER
Místo
AMSTERDAM
ISSN
2352-152X
Periodikum
Journal of Energy Storage
Ročník
56
Číslo
106143
Stát
Nizozemsko
Strany od
1
Strany do
17
Strany počet
URL
https://www.sciencedirect.com/science/article/pii/S2352152X22021326?via%3Dihub
BibTex
@article{BUT180629, author="Jakub {Čurpek} and Miroslav {Čekon}", title="Building performance simulation of a photovoltaic facade enhanced with latent heat storage: Model validation and power generation prediction", journal="Journal of Energy Storage", year="2022", volume="56", number="106143", pages="1--17", doi="10.1016/j.est.2022.106143", issn="2352-152X", url="https://www.sciencedirect.com/science/article/pii/S2352152X22021326?via%3Dihub" }