Detail publikace

CHEMICAL EVALUATION OF MEDICAL DEVICES (DENTAL COMPOSITES) PART 1

MRAVCOVÁ, L. FUČÍK, J.

Originální název

CHEMICAL EVALUATION OF MEDICAL DEVICES (DENTAL COMPOSITES) PART 1

Typ

zpráva odborná

Jazyk

angličtina

Originální abstrakt

Chemical characterization of extracts from two dental composite materials (FD4X Fibrafill Dentin and ever X Posterior) was carried out. Materials were extracted into three extraction liquids (water, buffer – PBS, 100% ethanol) at two different temperatures (37 °C and 50 °C). The LC-MS analysis proved that dental material from ADM, a.s. is equally biocompatible to the reference material from GC EUROPE N.V. in extractability of substances and therefore their biocompatibility should be similar as well.

Klíčová slova

dental composites, monomers, substances of photoinitiator system,extraction, diffusion, liquid chromatrography, mass spectrometry

Autoři

MRAVCOVÁ, L.; FUČÍK, J.

Vydáno

12. 11. 2020

Strany od

1

Strany do

16

Strany počet

16

BibTex

@techreport{BUT181566,
  author="Ludmila {Mravcová} and Jan {Fučík}",
  title="CHEMICAL EVALUATION OF MEDICAL DEVICES (DENTAL COMPOSITES) PART 1",
  year="2020",
  pages="1--16"
}