Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
RIZZO, R. DZIADOSZ M. KYATHANAHALLY, S.P. SHAMAEI, A. KREIS, R.
Originální název
Quantification of MR spectra by deep learning in an idealized setting: Investigation of forms of input, network architectures, optimization by ensembles of networks, and training bias
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Purpose: The aims of this work are (1) to explore deep learning (DL) architectures, spectroscopic input types, and learning designs toward optimal quantification in MR spectroscopy of simulated pathological spectra; and (2) to demonstrate accuracy and precision of DL predictions in view of inherent bias toward the training distribution. Methods: Simulated 1D spectra and 2D spectrograms that mimic an extensive range of pathological in vivo conditions are used to train and test 24 different DL architectures. Active learning through altered training and testing data distributions is probed to optimize quantification performance. Ensembles of networks are explored to improve DL robustness and reduce the variance of estimates. A set of scores compares performances of DL predictions and traditional model fitting (MF). Results: Ensembles of heterogeneous networks that combine 1D frequency-domain and 2D time-frequency domain spectrograms as input perform best. Dataset augmentation with active learning can improve performance, but gains are limited. MF is more accurate, although DL appears to be more precise at low SNR. However, this overall improved precision originates from a strong bias for cases with high uncertainty toward the dataset the network has been trained with, tending toward its average value. Conclusion: MF mostly performs better compared to the faster DL approach. Potential intrinsic biases on training sets are dangerous in a clinical context that requires the algorithm to be unbiased to outliers (i.e., pathological data). Active learning and ensemble of networks are good strategies to improve prediction performances. However, data quality (sufficient SNR) has proven as a bottleneck for adequate unbiased performance-like in the case of MF.
Klíčová slova
active learning; bias; deep learning; ensemble of networks; model fitting; magnetic resonance spectroscopy; quantification
Autoři
RIZZO, R.; DZIADOSZ M.; KYATHANAHALLY, S.P.; SHAMAEI, A.; KREIS, R.
Vydáno
30. 12. 2022
Nakladatel
WILEY
Místo
HOBOKEN
ISSN
0740-3194
Periodikum
MAGNETIC RESONANCE IN MEDICINE
Ročník
1
Číslo
Stát
Spojené státy americké
Strany od
Strany do
21
Strany počet
URL
https://onlinelibrary.wiley.com/doi/epdf/10.1002/mrm.29561
BibTex
@article{BUT182576, author="RIZZO, R. and DZIADOSZ M. and KYATHANAHALLY, S.P. and SHAMAEI, A. and KREIS, R.", title="Quantification of MR spectra by deep learning in an idealized setting: Investigation of forms of input, network architectures, optimization by ensembles of networks, and training bias", journal="MAGNETIC RESONANCE IN MEDICINE", year="2022", volume="1", number="1", pages="1--21", doi="10.1002/mrm.29561", issn="0740-3194", url="https://onlinelibrary.wiley.com/doi/epdf/10.1002/mrm.29561" }