TRÁVNÍČEK, V. KLIMEŠ, P. CIMBÁLNÍK, J. HALÁMEK, J. JURÁK, P. BRINKMANN, B. BALZEKAS, I. ABDOULAH, C. DUBEAU, F. WORRELL, G. BRÁZDIL, M.
Originální název
Relative entropy is an easy-to-use invasive electroencephalographic biomarker of the epileptogenic zone
Typ
článek v časopise ve Web of Science, Jimp
Jazyk
angličtina
Originální abstrakt
Objective: High-frequency oscillations are considered among the most promising interictal biomarkers of the epileptogenic zone in patients suffering from pharmacoresistant focal epilepsy. However, there is no clear definition of pathological high-frequency oscillations, and the existing detectors vary in methodology, performance, and computational costs. This study proposes relative entropy as an easy-to-use novel interictal biomarker of the epileptic tissue.Methods: We evaluated relative entropy and high-frequency oscillation biomarkers on intracranial electroencephalographic data from 39 patients with seizure-free postoperative outcome (Engel Ia) from three institutions. We tested their capability to localize the epileptogenic zone, defined as resected contacts located in the seizure onset zone. The performance was compared using areas under the receiver operating curves (AUROCs) and precision-recall curves. Then we tested whether a universal threshold can be used to delineate the epileptogenic zone across patients from different institutions.Results: Relative entropy in the ripple band (80-250 Hz) achieved an average AUROC of .85. The normalized high-frequency oscillation rate in the ripple band showed an identical AUROC of .85. In contrast to high-frequency oscillations, relative entropy did not require any patient-level normalization and was easy and fast to calculate due to its clear and straightforward definition. One threshold could be set across different patients and institutions, because relative entropy is independent of signal amplitude and sampling frequency.Significance: Although both relative entropy and high-frequency oscillations have a similar performance, relative entropy has significant advantages such as straightforward definition, computational speed, and universal interpatient threshold, making it an easy-to-use promising biomarker of the epileptogenic zone.
Klíčová slova
drug-resistant epilepsy; iEEG; SOZ localization
Autoři
TRÁVNÍČEK, V.; KLIMEŠ, P.; CIMBÁLNÍK, J.; HALÁMEK, J.; JURÁK, P.; BRINKMANN, B.; BALZEKAS, I.; ABDOULAH, C.; DUBEAU, F.; WORRELL, G.; BRÁZDIL, M.
Vydáno
10. 2. 2023
Nakladatel
WILEY
Místo
HOBOKEN
ISSN
0013-9580
Periodikum
EPILEPSIA
Ročník
64
Číslo
4
Stát
Spojené státy americké
Strany od
962
Strany do
972
Strany počet
11
URL
https://onlinelibrary.wiley.com/doi/10.1111/epi17539
BibTex
@article{BUT184402, author="Vojtěch {Trávníček} and Petr {Klimeš} and Jan {Cimbálník} and Josef {Halámek} and Pavel {Jurák} and Benjamin H. {Brinkmann} and Irena {Balzekas} and Chifaou {Abdoulah} and Francois {Dubeau} and Gregory {Worrell} and Milan {Brázdil}", title="Relative entropy is an easy-to-use invasive electroencephalographic biomarker of the epileptogenic zone", journal="EPILEPSIA", year="2023", volume="64", number="4", pages="962--972", doi="10.1111/epi.17539", issn="0013-9580", url="https://onlinelibrary.wiley.com/doi/10.1111/epi17539" }