Detail publikace

Primary Calibration of Acoustic Emission Sensors

KEPRT, J.

Originální název

Primary Calibration of Acoustic Emission Sensors

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

The paper reviews the background, the methodology and the standardization of the primary calibration of acoustic emission sensors. Two basic calibration methods, which were practically realized on our test stand, are closely described and explained. It is the method of reciprocity calibration according to [NDIS 2109, 1991] and the step function calibration according to [ASTM 1106, 1986]. As a transfer medium for wave propagation a large steel block was used. The comparison of the results of the both method is presented.

Klíčová slova

acoustic emission, sensor calibration, ASTM 1106, NDIS 2109

Autoři

KEPRT, J.

Rok RIV

2007

Vydáno

24. 5. 2007

Nakladatel

TU Košice, BERG Faculty

Místo

Košice

ISBN

978-80-8073-805-1

Kniha

Proceedings of 8th international Carpathian Control Conference

Číslo edice

1

Strany od

287

Strany do

290

Strany počet

4

BibTex

@inproceedings{BUT22515,
  author="Jiří {Keprt}",
  title="Primary Calibration of Acoustic Emission Sensors",
  booktitle="Proceedings of 8th international Carpathian Control Conference",
  year="2007",
  number="1",
  pages="4",
  publisher="TU Košice, BERG Faculty",
  address="Košice",
  isbn="978-80-8073-805-1"
}