Přístupnostní navigace
E-přihláška
Vyhledávání Vyhledat Zavřít
Detail publikace
JEDELSKÝ, J. LÍZAL, F. JÍCHA, M.
Originální název
Particle Motion in a Realistic Human Airway Model under Steady and Cyclic Flows
Typ
článek ve sborníku ve WoS nebo Scopus
Jazyk
angličtina
Originální abstrakt
Transparent realistic human airway model with non-symmetric bifurcations and non-planar geometry containing parts from throat to 3rd-4th generation of bronchi was used for study of a transport of micron-size liquid aerosol particles. Velocity of the particles in a size range 1 to7 microns was measured under steady and cyclic flow conditions using Phase Doppler Analyser. Significant differences between steady and cyclic particle flows were found. Specific particle flow patterns under cyclic breathing are documented in the paper.
Klíčová slova
Particle Motion, Realistic Human Airway Model, Cyclic Flows, Phase Doppler Anemometry
Autoři
JEDELSKÝ, J.; LÍZAL, F.; JÍCHA, M.
Rok RIV
2010
Vydáno
1. 6. 2010
Nakladatel
Institute of Hydrodynamics ASCR
Místo
Praha
ISBN
978-80-87117-07-1
Kniha
24th SYMPOSIUM ON ANEMOMETRY, PROCEEDINGS
Edice
1
Číslo edice
Strany od
57
Strany do
63
Strany počet
7
BibTex
@inproceedings{BUT29904, author="Jan {Jedelský} and František {Lízal} and Miroslav {Jícha}", title="Particle Motion in a Realistic Human Airway Model under Steady and Cyclic Flows", booktitle="24th SYMPOSIUM ON ANEMOMETRY, PROCEEDINGS", year="2010", series="1", number="1", pages="57--63", publisher="Institute of Hydrodynamics ASCR", address="Praha", isbn="978-80-87117-07-1" }