Detail publikace

Check valve slam analysis in pumping station

HIMR, D. HABÁN, V. DOKOUPIL, P.

Originální název

Check valve slam analysis in pumping station

Typ

článek ve sborníku ve WoS nebo Scopus

Jazyk

angličtina

Originální abstrakt

Pumping station supplies water for technological process. The check valve in the station was replaced with a new one. The regular test of black out discovered the high pressure pulsations accompanied with noticeable pipeline movement of discharge pipe. It was caused by late check valve closing, probably, when the back flow reached the highest possible velocity. This statement was supported with analysis of results of pressure measurement near the check valve and with a numerical simulation of the flow in the pipeline system.

Klíčová slova

water hammer, check valve

Autoři

HIMR, D.; HABÁN, V.; DOKOUPIL, P.

Vydáno

28. 3. 2016

Nakladatel

EDP Sciences

ISSN

2100-014X

Periodikum

EPJ Web of Conferences

Ročník

114

Číslo

2016

Stát

Francouzská republika

Strany od

1

Strany do

6

Strany počet

6

URL

Plný text v Digitální knihovně

BibTex

@inproceedings{BUT123443,
  author="Daniel {Himr} and Vladimír {Habán} and Pavel {Dokoupil}",
  title="Check valve slam analysis in pumping station",
  booktitle="EPJ Web of Conferences",
  year="2016",
  journal="EPJ Web of Conferences",
  volume="114",
  number="2016",
  pages="1--6",
  publisher="EDP Sciences",
  doi="10.1051/epjconf/201611402038",
  issn="2100-014X",
  url="http://www.epj-conferences.org/articles/epjconf/abs/2016/09/epjconf_efm2016_02038/epjconf_efm2016_02038.html"
}