Originální abstrakt
Within a flow measurement and mapping chamber there is an extreme static pressure stability required to maintain static environmental conditions around the main center axis where all dynamic measurements and mapping take place. To be able to achieve such accurate pressure control a very accurate pressure measurement is required. This article aims at the use of a strain gauge for precise static pressure measurement within a flow measurement and mapping chamber.
Klíčová slova
ANSYS Fluent, Electron microscopy, Pressure gauge, SolidWorks
Autoři
Vydáno
26. 8. 2018
Nakladatel
Brno University of Technology
Místo
Brno
ISBN
978-80-214-5651-8
Kniha
Advanced Batteries Accumulators and Fuel Cells – 19th ABAF
Edice
19
Číslo edice
1
Strany od
145
Strany do
147
Strany počet
3
BibTex
@inproceedings{BUT149605, author="Robert {Bayer}", title="Static pressure measurement within a flow measurement and mapping chamber", booktitle="Advanced Batteries Accumulators and Fuel Cells – 19th ABAF", year="2018", series="19", number="1", pages="145--147", publisher="Brno University of Technology", address="Brno", isbn="978-80-214-5651-8" }